DigiPuls
Practice space — nothing here is saved.

Model Lyceum (practice school) — Cycle 2

Order 675 compliance data

This feeds D1 and D2's Level-0 determination directly — see the compliance panel below.

Checks declared equipment quantities (Annex 2) and the network checklist (Annex 5) only — technical specifications (Annex 1), supplementary equipment (Annex 3) and room-usage mandates (Annex 4) are not yet verified by this system. "Compliant" here means "meets the quantities/checklist DigiPuls currently checks", not full Order 675 verification.

Device inventory

For each kind of equipment, how many the school has in total. How many of those are out of use is counted from the write-off register below, and only the difference counts towards the Order 675 minimum: equipment that cannot be put in front of a class does not equip one.

5 for write-off

4 for write-off

Network checklist

Equipment for write-off

Equipment that is in the school and can no longer be used. Recording it here is how the Ministry and partners read what a school can actually teach with, rather than what is on its books. Each line is counted out of the Order 675 totals until it leaves the school.

The “out of use” figures in the inventory above are counted from this register. Nothing is typed twice.

11 pieces of equipment on 3 lines, of which 11 are still in the school.

Equipment recorded for write-off
Equipment How many Why Acquired Stage Note
Classroom PCs/laptops 5 Too old for current software 2011 Proposed for write-off —
IT-room PCs 4 Broken beyond repair 2009 Write-off approved, not yet removed —
Projectors 2 No parts or service available 2013 In the school, not yet proposed —
Moving or removing a line of the register
Equipment Stage Actions
Classroom PCs/laptops — 5
IT-room PCs — 4
Projectors — 2

Kinds marked * are not counted by the Order 675 quota; record them anyway, so the picture of the school is whole.

D2 — Order 675 quantitative equipment check (Band 251-500) NON-COMPLIANT

Requirement Required Held For write-off Actual Status
Classroom PCs/laptops (≥50% of classrooms equipped) 12 12 5 7 SHORT
Interactive panels (1 per equipped classroom) 12 6 0 6 SHORT
IT-room PCs (3 room(s) × 15) 45 18 4 14 SHORT
Management PCs/laptops 3 4 0 4 OK
Methodical-centre PCs/laptops 3 2 0 2 SHORT
Library PCs/AiOs 4 5 0 5 OK
Printers 1 2 0 2 OK
Multifunction printers 1 1 0 1 OK

D1 — Order 675 network checklist NON-COMPLIANT

RequirementStatus
Whole-school WiFi/LAN coverage OK
≥2–3 separated, password-protected subnets (administration/teachers, students, guest) MISSING
802.11n WiFi standard (40MHz, 600Mbps, 2.4+5GHz) OK
802.11ac WiFi standard (up to 160MHz, 1Gbps, 5GHz) OK
Active firewall OK
Content filtering for the student network MISSING

Note: If D1 or D2 above is non-compliant, that indicator's rating is capped at Level 0 regardless of what is selected in the picker — non-compliance with Order 675 is Level 0 by definition.